Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
RGO (Porto Alegre) ; 67: e20190024, 2019. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1012904

ABSTRACT

ABSTRACT Objective: Performing an in vitro evaluation of the biological effects on cell growth and viability of fibroblasts in PLGA membranes with and without simvastatin. Methods: Two groups of resorbable synthetic polymeric membranes were used: PLGA, with and without simvastatin, cut into a suitable format to fit to 24 thermometric wells. Fibroblasts were grown on resorbable membranes and evaluated for proliferation and viability at 24, 48 and 72 hours after the beginning of cultivation, being the tests performed in triplicate. For the cell growth analysis, the Trypan blue exclusion method was applied, while cell viability was observed by the MTT test. The results were statistically analyzed applying the Two-Way ANOVA, followed by the Bonferroni test, with 95% confidence interval and P value smaller than 0.05 was accepted as statistically significant. Results: Statistical difference (p <0.01) was seen between the control group (2.16x104 ± 0.51 cells) and the PLGA group with simvastatin (1.58x104 ± 0.36 cells) in the 48-hour period. After 72 hours, statistical differences (p <0.001) were observed between the PLGA group with simvastatin (1.66x104 ± 0.49 cells) and the PLGA group without simvastatin (2.25x104 ± 0.2 cells) when compared to the control group (2.81x104 ± 0.33 cells) for cell proliferation. Statistical differences (p <0.05) were observed between the control group (0.27 ± 0.05) and the PLGA group with simvastatin (0.21 ± 0.03). Likewise, a statistical difference (p <0.001) was seen between the PLGA group without simvastatin (0.19 ± 0.02) and the control group after 24 hours. In the 48 - 72-hour period, statistical differences (p <0.001) were observed between the control group (0.36 ± 0.09 and 0.55 ± 0.05, after 48 and 72 hours respectively) and the PLGA group without simvastatin (0.26 ± 0.05 and 0.34 ± 0.07, after 48 and 72 hours respectively), as well as in the PLGA group with simvastatin (0.27 ± 0.04 and 0.31 ± 0, 04, after 48 and 72 hours respectively) for the cell viability test. Conclusion: The association of simvastatin to PLGA membranes had an inhibitory effect on fibroblast proliferation, as well as induced a reduction in cell viability. Thus, the use of PLGA along with simvastatin may assist in guided bone regeneration.


RESUMO Objetivo: Esse trabalho avaliou, in vitro, os efeitos biológicos no crescimento e viabilidade celular de fibroblastos em membranas de PLGA com e sem sinvastatina. Materiais e métodos: Foram utilizados dois grupos de membranas reabsorvíveis de polímeros sintéticos: PLGA com sinvastantina e sem sinvastantina, recortadas em formato apropriado para adaptar nas placas de 24 wells termométricas. Os fibroblastos foram cultivados em membranas reabsorvíveis, sendo avaliadas em relação à proliferação e viabilidade em 24, 48 e 72 horas após o início do cultivo, os testes foram realizados em triplicata. Para a análise do crescimento celular foi utilizado o método de exclusão vital azul de Tripan, enquanto a viabilidade celular foi observada pelo teste MTT. Os resultados obtidos foram estatisticamente analisados utilizando Two-Way ANOVA, seguido pelo teste de Bonferroni, com intervalo de confiança de 95% e um valor de P inferior a 0,05 foi aceito como estatisticamente significativo. Resultados: Foi observado diferença estatística (p<0,01) entre o grupo controle (2,16x104 ± 0,51 células) e o grupo PLGA com sinvastatina (1,58x104 ± 0,36 células) no período de 48 horas. Após 72 horas, diferenças estatísticas (p<0,001) foram observadas entre o grupo PLGA com sinvastatina (1,66x104 ± 0,49 células) e o grupo PLGA sem sinvastatina (2,25x104 ± 0,2 células) em comparação ao grupo controle (2,81x104 ± 0,33 células) quanto a proliferação celular. Diferenças estatísticas (p<0,05) foram observadas entre o grupo controle (0,27 ± 0,05) e o grupo PLGA com sinvastatina (0,21 ± 0,03), da mesma forma que, diferença estatística (p<0,001) foram observadas entre o grupo PLGA sem sinvastatina (0,19 ± 0,02) e grupo controle após 24 horas. No período de 48 horas e 72 horas diferenças estatísticas (p<0,001) foram observadas entre o grupo controle (0,36 ± 0,09 e 0,55 ± 0,05, após 48 e 72 horas respectivamente) e o grupo PLGA sem sinvastatina (0,26 ± 0,05 e 0,34 ± 0,07, após 48 e 72 horas respectivamente), assim como, o grupo PLGA com sinvastatina (0,27 ± 0,04 e 0,31 ± 0,04, após 48 e 72 horas respectivamente) quanto ao teste de viabilidade celular. Conclusão: A associação de sinvastatina às membranas de PLGA apresentou um efeito inibitório na proliferação de fibroblastos, bem como induziu uma redução da viabilidade celular destes, deste modo, sugere-se a utilização de PLGA associado à sinvastatina como uma ferramenta para auxiliar na regeneração óssea guiada.

2.
ImplantNews ; 12(5): 603-606, 2015.
Article in Portuguese | LILACS, BBO | ID: lil-767514

ABSTRACT

Este manuscrito descreve as atividades desenvolvidas na PPGO/UFSC, concentradas em três linhas de pesquisa: 1) neoformação óssea peri-implantar; 2) engenharia tecidual; e 3) microbiologia aplicada à Implantodontia. Na linha um, diversos métodos analíticos quantitativos e qualitativos (SEM, AFM, FTIR, OCP, EIS, FEG-SEM) têm sido usados para investigação de diferentes intensidades de corrente elétrica na superfície do Ti-cp e Ti-6Al-4V, quando imersos em meios fisiológicos simulados, na adsorção de proteínas, proliferação celular com fibroblastos, queratinócitos e osteoblastos. Na linha dois, o desenvolvimento in vitro de um arcabouço poroso de PLGA e cerâmica bifásica, incorporado com sinvastatina, sera testado in vivo na resposta de fibroblastos gengivais provenientes de cultura primaria, em meio de cultura com plasma rico em plaquetas (PRP), depositado sobre matriz dérmica acelular e matriz de celulose bacteriana (BC). A linha três concentra a atuação com dois centros internacionais (Belgica e EUA) para a incorporação de compostos antibiofilme em polímeros biocompatíveis, e verificação da eficiência de um método de liberação prolongada de antibióticos incorporados em superfícies nanoestruturadas. Estes projetos devem resultar em melhoria de saúde aos pacientes e no desenvolvimento econômico e social da comunidade.


This paper describes the activities developed at PPGO/UFSC divided into three research lines: 1) peri-implant bone neoformation; 2) tissue engineering, and 3) microbiology applied to implant dentistry. On the first line, several quantitative and qualitative (SEM, AFM, FTIR, OCP, EIS, FEG-SEM) analytical methods have been used to investigate the different electric current intensities on Ti c.p. and Ti6Al4V implant surfaces when immersed into simulated physiological media, protein adsorption, cell proliferation with fibroblasts, keratinocytes, and osteoblasts. On the second line, the in vitro development of a 3D PLGA and biphasic ceramic, simvastatin-incorporated scaffold will be tested in vivo for gingival fibroblast response from primary culture in platelet-rich plasma (PRP) enriched vehicle over an acellular dermal (Sure- Derm) and bacterial cellulose matrix (BC). For line three, two international research centers (Belgium and USA) joined common efforts to incorporate polymer anti-biofi lm compounds and to verify the efficiency of a prolonged release method for antibiotics attached to nanostructured surfaces. All those projects must result in better health conditions and social and economic development of our community.


Subject(s)
Microbiology , Osteogenesis , Tissue Engineering
3.
RSBO (Impr.) ; 11(1): 59-65, Jan.-Mar. 2014. ilus
Article in English | LILACS | ID: lil-718007

ABSTRACT

Introduction: The challenge of restoring patient's function that presented some loss of an organ or tissue encourages the Tissue Engineering and Biotechnology to develop materials that promote bone regeneration. Poly(lactic-co-glycolic acid) (PLGA) copolymer is among of the most biomaterials used. Objective: To evaluate the tensile strength of PLGA membranes at different conditions of humidity and temperature. Material and methods: PLGA membranes were hourglass-shape cut and prepared at three different conditions of temperature and humidity (n = 10): (I) dry membrane at environment temperature of about 20ºC (control group), (II) moist membrane plasticized at 55ºC, (III) moist membrane plasticized at 55ºC, which subsequently underwent cooling. Subsequently, the membranes were subjected to tensile tests in a universal testing machine (DL-2000, EMIC) at 1.0 mm/min. Data was submitted to ANOVA and Tukey's test (p < 0.05). Results: Group I showed the highest tensile strength mean (16.7 ± 1.9a MPa, p = 0.0022). There was no statistically significant difference between the means of groups II (14.6 ± 1.4 MPab) and III (13.9 ± 1.7 MPab). Conclusion: The dried PLGA membranes showed higher tensile strength than the membranes that were only either plasticized or cooled.

4.
Ortho Sci., Orthod. sci. pract ; 3(10): 139-144, 2010. ilus
Article in Portuguese | LILACS, BBO | ID: lil-563029

ABSTRACT

O mini-implante é um dispositivo utilizado pelos ortodontistas como um método de ancoragem, eliminando em grande parte a necessidade de cooperação dos pacientes e ampliando as possibilidades de tratamento em diversos tipos de movimentos ortodônticos. O presente trabalho teve como objetivo realizar uma revisão da literatura, discorrendo sobre as diversas aplicações clínicas do miniimplante, suas vantagens e desvantagens, o procedimento cirúrgico, demonstrar a técnica para localização exata do sitio de instalação do mini-implante e ainda relatar um caso clínico de paciente portadora de sintomatologia dolorosa da ATM, mordida cruzada e desvio da linha média, onde o plano de tratamento foi a utilização de mini-implante associado a barra transpalatina. De acordo com a literatura consultada pode-se concluir que o mini-implante é bastante efetivo como dispositivo de ancoragem.


The mini screws are devices used by orthodontists as a method of anchorage, largely eliminating the need for patient cooperation and expanding the possibilities for treatment in various types of orthodontic movements. This study aimed to conduct a review of the literature, discussing the various clinical applications of the mini screw, their advantages and disadvantages, surgical procedures, demonstrate exact localization technique of the installation site mini screw and also report a case of a patient with symptoms of TMJ pain, cross bite and deviation midline, where the treatment plan was the use of mini-implants associated with transpalatal bar. According to the literature and after completion of the case, one can conclude that the mini screw was quite effective as a method of anchorage the correction of midline.


Subject(s)
Orthodontic Anchorage Procedures
5.
Bauru; s.n; 1997. 105 p. ilus.
Thesis in Portuguese | LILACS, BBO | ID: lil-250283

ABSTRACT

O propósito deste estudo foi avaliar 42 molares decíduos submetidos à pulpotomia, por indicaçäo clínica, cujo capeamento pulpar foi feito com hidroxiapatita microgranular sintetizada no Departamento de Bioquímica da Faculdade de Odontologia de Bauru da Universidade de Säo Paulo. O material capeador foi usado em 21 dentes sob a forma de material pó, e 21 dentes na forma de pasta (21), sendo esta pasta preparada no momento de intervençäo, por meio da adiçäo de uma soluçäo antiinflamatória ao pó de hidroxiapatita. Após o período de 6 meses foram realizadas análises clínica e radiográfica. Com base nos resultados obtidos, segundo as condiçöes experimentais em que foi realizado este trabalho, podem-se verificar que: a análise radiográfica quando associada a análise clínica como controle pós-operatório é mais segura que somente a análise clínica; o material capeador pulpar na forma de pasta pareceu ser melhor aceito pelos tecidos pulpares que o na forma de pó; a adiçäo de uma soluçäo antiinflamatória ao pó para formar a pasta pode ter sido responsável pela tendência de maior sucesso com o material na forma de pasta; a hidroxiapatita microgranular pode ser considerada uma opçäo como material regenerador na técnica de pulpotomia em dentes decíduos


Subject(s)
Humans , Male , Female , Child, Preschool , Child , Dental Pulp Capping/methods , Durapatite/analysis , Tooth, Deciduous/chemistry , Biocompatible Materials/analysis , Dental Materials/analysis , Molar/chemistry , Pediatric Dentistry , Pulpotomy
6.
Rev. Fac. Odontol. Bauru ; 2(3): 1-4, jul. 1994. ilus
Article in Portuguese | LILACS, BBO | ID: lil-222498

ABSTRACT

A fusäo e a geminaçäo representa 1 por cento das anomalias dentárias. Em crianças de pouca idade, onde há necessidade de extraçäo é importante restabelecer a funçäo e a estética. Nestes casos, a colaboraçäo do paciente no tratamento nem sempre é positiva sendo necessário o uso de uma técnica reabilitadora simples e eficaz. A reabilitaçäo de uma prótese adesiva no local foi o tratamento de eleiçäo neste caso apresentado


Subject(s)
Humans , Male , Child, Preschool , Denture, Partial, Fixed, Resin-Bonded , Tooth, Deciduous , Tooth Abnormalities/pathology , Pathology, Oral , Pediatric Dentistry
7.
Rev. Fac. Odontol. Bauru ; 2(3): 22-5, jul. 1994.
Article in Portuguese | LILACS, BBO | ID: lil-222502

ABSTRACT

Devido à importância das coroas de aço em odontopediatria, muitas técnicas operatórias têm sido apresentadas com o objetivo de aumentar sua resistência e adaptaçäo. Uma revisäo de literatura a este respeito será apresentrada


Subject(s)
Humans , Male , Female , Child , Dental Cements/analysis , Tooth Crown/surgery , Dental Restoration, Permanent , Glass Ionomer Cements/analysis , Pediatric Dentistry , Polycarboxylate Cement/adverse effects , Polycarboxylate Cement/analysis , Zinc Phosphate Cement/adverse effects , Zinc Phosphate Cement/analysis
SELECTION OF CITATIONS
SEARCH DETAIL